Komatsu 830E-AC Shop Manual page 401

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

EVENT
NUMBER
DESCRIPTION
113/213
INVERTER, GENERAL
:01
Aup cur hi
:02
Adn cur hi
:03
Bup cur hi
:04
Bdn cur hi
:05
Cup cur hi
:06
Cdn cur hi
:07
Aup cur lo
:08
Adn cur lo
:09
Bup cur lo
:10
Bdn cur lo
:11
Cup cur lo
:12
Cdn cur lo
:13
A zero cur hi
:15
B zero cur hi
:17
A volt hi Adn
:18
A volt lo Aup
:19
A volt hi Bdn
:20
A volt lo Bup
:21
A volt hi Cdn
:22
A volt lo Cup
:23
B volt hi Adn
:24
B volt lo Aup
:25
B volt hi Bdn
:26
B volt lo Bup
:27
B volt hi Cdn
:28
B volt lo Cup
:29
C volt hi Adn
:30
C volt lo Aup
:31
C volt hi Bdn
:32
C volt lo Bup
:33
C volt hi Cdn
:34
C volt lo Cup
:35
Aup fault cur
:36
Adn fault cur
:37
Bup fault cur
:38
Bdn fault cur
:39
Cup fault cur
:40
Cdn fault cur
:48
A volt hi off
:49
A volt lo off
E02020 10/06
Table 3: DID PANEL FAULT CODES
(Codes Received from Inverter 1 & 2)
EVENT
RESTRICTION
Electrical Propulsion System Components
EVENT
Phase A current out too high
Phase A current in too high
Phase B current out too high
Phase B current in too high
Phase C current out too high
Phase B current in too high
Phase A current out too low
Phase A current in too low
Phase B current out too low
Phase B current in too low
Phase C current out too low
Phase C current in too low
Phase A current out not zero
Phase B current out not zero
Phase A volt too high while phase A down on
Phase A volt too low while phase A up on
Phase A volt too high while phase B down on
Phase A volt too low while phase B up on
Phase A volt too high while phase C down on
INV1 (INV2) off
Phase A volt too low while phase C up on
Phase B volt too high while phase A down on
Phase B volt too low while phase A up on
Phase B volt too high while phase B down on
Phase B volt too low while phase B up on
Phase B volt too high while phase C down on
Phase B volt too low while phase C up on
Phase C volt too high while phase A down on
Phase C volt too low while phase A up on
Phase C volt too high while phase B down on
Phase C volt too low while phase B up on
Phase C volt too high while phase C down on
Phase C volt too low while phase C up on
Phase A fault current when phase A up on
Phase A fault current when phase A down on
Phase B fault current when phase B up on
Phase B fault current when phase B down on
Phase C fault current when phase C up on
Phase C fault current when phase C down on
Phase A voltage high with all IGBTs off
Phase A voltage low with all IGBTs off
DETECTION
INFORMATION
E2-17