Komatsu 830E-AC Shop Manual page 854

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

Sorting on Date Range
The default query starts in 1995 and runs through the
current date on the PC. To narrow the range to a spe-
cific date, change the "From" and "To" dates.
For example, to view the haul cycle reports from
truck 374 for the month of July, 2000:
1. Select truck 374 from the Truck Unit pull-down
menu.
2. Change the "From" date to July 1, 2000.
3. Change the "To" date to July 31, 2000.
4. Press the "Query Database and Display" to
view the results.
Sorting on Time Range
The time range sorts the times of the day for valid
dates. Changing the time range to 6:00AM to 6:00PM
will limit the payloads displayed to the loads that
occurred between those times for each day of the
date range. Times are entered in 24:00 format. To
view the haul cycle reports from the first shift for truck
374 from January 5, 2000 to January 8, 2000:
1. Select truck 374 from the Truck Unit pull-down
menu.
M20-26
2. Change the "From" date to January 5, 2000.
3. Change the "To" date to January 8, 2000.
4. Change the "From" time to 06:00.
5. Change the "To" time to 18:00.
6. Press the "Query Database and Display" to
view the results.
This query will display haul cycles from January 5 to
January 8, from 6:00 AM to 6:00 PM.
Time
Jan 5, 2000
0:00
6:00
12:00
18:00
24:00
Date: 1/5/00 to 1/8/00
Query :
Daily Shift Time: 6:00 to 18:00
The shift times selected can extend the query past
the original date. If the dates set for the query are
January 5 to January 8 and the times were changed
to query the 6:00 PM (18:00) to 6:00 AM (06:00) shift,
the results would extend into the morning of the 9th.
This can been seen in the following example:
Payload Meter III
Date
Jan 6, 2000
Jan 7, 2000
Jan 8, 2000
Haul Cycles Included in the Query
02/05 M20008
Jan 9, 2000