Komatsu 830E-AC Shop Manual page 787

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

1.) If pressure is still below 20 684 kPa (3000
psi), continue increasing engine speed in
steps of 300 rpm, while in third stage and
observing pressure gauge.
2.) Continue monitoring pressure gauge until
engine high idle is attained.
c. If gauge indicates 20 684 kPa (3000 psi)
while at high idle, in POWER UP and in third
stage, counterbalance valve adjustment is
correct.
d. If gauge does not indicate 20 684 kPa (3000
psi) while in third stage and at high idle (or a
lesser rpm during step 1b, 1.) perform Coun-
terbalance Valve Adjustment procedure.
L10028
Counterbalance Valve Adjustment
1. Loosen locknut on adjustment stem of counter-
balance valve (4, Figure 10-9) on manifold.
Turn adjustment stem fully clockwise to start
adjustment procedure so counterbalance valve
pressure is as low as possible.
Note: Turning adjustment stem in (clockwise)
decreases the pressure. Turning the stem out
(counterclockwise)
Complete valve adjustment range is 3 turns.
2. Start the engine and operate at high idle. Raise
the body while observing the pressure gauge.
3. Slowly adjust counterbalance valve to obtain 20
684 kPa (3000 psi) as the hoist cylinder 3rd
stage extends while in POWER UP. When
adjustment is complete, secure locknut on
adjustment stem.
4. Repeat Counterbalance Valve Pressure Check,
Step 1 to verify proper adjustment.
5. Replace fitting in PILOT VENT port (8).
Remove pressure gauge.
6. Turn needle valve adjustment stem (9) out 3
turns and secure locknut.
Hydraulic Check-out Procedure
increases
the
pressure.
L10-19

Advertisement

Table of Contents
loading