Komatsu 830E-AC Shop Manual page 393

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

EVENT
NUMBER
DESCRIPTION
014
ANALOG SENSOR FAULT
:01
alt field amps
:02
link amps
:03
load box amps
:04
3 phase alt volts
:05
alt field volts
:10
PSC link volts
:11
inv1 link volts
:12
inv2 link volts
:13
A2D ground
:14
A2D gain
:15
fault current
:16
ATOC
:21
grid blower 1 amps
:22
grid blower 2 amps
015
ANALOG SENSOR FAULT (restrictive)
:02
link amps
016
PSC CPU CARD (FB147)
:01
task_1
:02
task_2
:03
task_3
:04
task_4
:05
task_5
:06
task_6
:07
maintenance task
:09
flash CRC
:10
BRAM CRC
:11
excess timeouts
:12
invalid pointers (data pack corrupted)
017
DIGITAL I/O CARD FAULT (FB104)
018
ANALOG I/O CARD FAULT (FB173)
:01
analog card no response
:02
analog card timeout
019
RIDING RETARD PEDAL
020
LO SPEED HI TORQUE TIMEOUT
E02020 10/06
Table 2: DID PANEL FAULT CODES
(Codes Received from PSC)
EVENT
RESTRICTION
Electrical Propulsion System Components
EVENT
Speed limit
Incorrect input from a sensor
Speed limit
Incorrect input from a sensor
Problem has occurred in the system CPU card.
Failed to initialize
No power
Flash CRC computation did not match expected value.
CRC on BRAM does not match expected value.
On power up, excessive timeouts occurred.
On power up, the status of data in BBRAM is invalid.
No power
System CPU cannot communicate with digital I/O card.
System CPU cannot communicate with analog I/O card.
No power
Card missing
Read timeout
SYS Event
Brake pedal applied while truck speed is >5 mph
No propel
Torque limit exceeded
DETECTION
INFORMATION
E2-9

Advertisement

Table of Contents
loading

Table of Contents