Komatsu 830E-AC Shop Manual page 882

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

NOTE: The gauge will quickly display the type of
information being displayed every 1 minute. For
example, if the left-front pressure is being displayed,
Lf=
will quickly display every minute. Only the
PL=
payload display,
does not display this infor-
mation.
9. Press and hold the "SELECT" button on the
Id=
dashboard.
will be displayed. Release
the button and the Operator ID will be dis-
played. This value should be 0.
10. Press and hold the "SELECT" button on the
tL=
dashboard.
will be displayed. Release
the button and the total tons will be displayed.
This value should be 0.
11. Press and hold the "SELECT" button on the
LC=
dashboard.
the button and the number of loads will be dis-
played. This value should be 0.
12. Press and hold the "SELECT" button on the
Lf=
dashboard.
will be displayed. Release
the button and the left-front pressure will be dis-
played. This value should be in metric units.
The nominal value should be 23.4 kg/cm
(332psi).
Values between 17.6 and 29.2 kg/
2
cm
(250 psi and 416 psi) are acceptable.
13. Press and hold the "SELECT" button on the
rf=
dashboard.
will be displayed. Release
the button and the right-front pressure will be
displayed. This value should be in metric units.
The nominal value should be 23.4 kg/cm
(332psi).
Values between 17.6 and 29.2 kg/
2
cm
(250 psi and 416 psi) are acceptable.
14. Press and hold the "SELECT" button on the
Lr=
dashboard.
will be displayed. Release
the button and the left-rear pressure will be dis-
played. This value should be in metric units.
The nominal value should be 23.4 kg/cm
(332psi). Values between 17.6 and 29.2 kg/cm
(250 psi and 416 psi) are acceptable.
M20-54
will be displayed. Release
2
2
2
2
Payload Meter III
15. Press and hold the "SELECT" button on the
rr=
dashboard.
will be displayed. Release the
button and the right-rear pressure will be dis-
played. This value should be in metric units.
The nominal value should be 23.4 kg/cm
(332psi).
Values between 17.6 and 29.2 kg/
2
cm
(250 psi and 416 psi) are acceptable.
16. Press and hold the "SELECT" button on the
In=
dashboard.
will be displayed. Release
the button and the inclinometer value will be
displayed. This value is in degrees. The incline
will depend on how the truck is set during
assembly. Values between ±3° are acceptable.
It is not necessary to zero this reading by
adjusting the attitude of the inclinometer in the
buddy seat.
17. Press and hold the "SELECT" button on the
PL=
dashboard.
will be displayed. Release
the button and the current payload will be dis-
played.
18. Connect a laptop to the PLMIII system. Typically
an EF9160 download cable is used. The pay-
load meter connector is behind the buddy seat
on the back wall on the side of the PLMIII
mounting bracket. The laptop must have the
Payload Data Manager software installed.
19. Run the PC software.
20. From the main menu, select "Connect to Pay-
load Meter".
2
02/05 M20008

Advertisement

Table of Contents
loading

Table of Contents