Komatsu 830E-AC Shop Manual page 849

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

PLM III SYSTEM CONFIGURATION
Starting Communications
The PDM software allows users to download and
configure the system.
Before connecting to the payload meter, select
"Change Program Options" and confirm that the pro-
gram has selected the correct laptop serial port. Most
laptops use Comm 1 for serial communications. The
units displayed for reports and graphs by the PC soft-
ware can be set on this form. Click "Done" to return
to the main menu.
From the main menu, click the "Connect to Payload
Meter" button. The PC will try to connect to the pay-
load meter and request basic information from the
system. In the event of communications trouble, the
PC will try 3 times to connect before "timing-out".
This may take several seconds.
Displayed Payload Units
Three options are available for the display of units in
the PC software, reports, and graphs:
M20008 02/05
Short Tons: Payload is displayed in short tons, dis-
tances and speeds will be displayed in Miles
Metric Tons: Payload is displayed in metric tons, dis-
tances and speeds are displayed in Kilometers
Long Tons: Payload is displayed in long tons, dis-
tances and speeds are displayed in Miles
Time Units
Minutes and Seconds Example:
Five minutes and thirty-two seconds = 5:32
Decimal Minutes Example:
Five minutes and thirty-two seconds = 5.53
Connection Menu
The connection screen displays basic system infor-
mation to the user.
• Frame S/N should agree with the truck serial
number from the serial plate located on the truck
frame.
• Truck Number is an ID number assigned to the
truck by the mine.
• The Payload Meter Date / Time values come
from the payload meter at the moment of
connection.
• Number of Haul Cycle Records is the number of
haul cycles records stored in memory and
available for download.
• Number of Active Alarms shows how many
alarms are currently active in the system at the
time of connection. If there are active alarms, the
"Display Active Alarms" button is available.
• Number of Inactive Alarms shows how many
alarms have been recorded in memory and are
available for download.
• PLM Software Version displays the current
version of software in the payload meter.
The information on the connection menu comes from
the configuration of the payload system on the truck.
Payload Meter III
M20-21