6.9

Executing the Program

Execute the program as described in the following:
• Since the [Go] check box under [Synchronization options] in the [Configuration] dialog box is
enabled, execute the program by selecting [Go] from the [Debug] menu of the High-
performance Embedded Workshop for CPU1, and then selecting [Go] from the [Debug] menu
or selecting the [Go] button on the toolbar of the High-performance Embedded Workshop for
CPU0.
Once program execution has started, '**RUNNING' will be displayed on the status bar, and will
be accompanied by the PC value (address) of the function being executed in the case of products
that support acquisition of the CPU state. The program will be executed up to any breakpoint that
has been set in the High-performance Embedded Workshop for CPU1, and an arrow will be
displayed in the [S/W breakpoint] column to indicate the position where the program was
suspended, with the message [BREAKPOINT] in the status bar.
Notes: 1. When the source file is displayed after a break, a path of the source file may be
inquired. The location of the source file is as follows:
<Drive where the OS has been installed>:
\WorkSpace\Tutorial\E10A-USBM\SH2A-DUAL\SH2A-DUAL\Tutorial_SH2A-
DUAL\CPU1.
2. If program execution is failed, select [Reset CPU] from the [Debug] menu, reset the
device, and restart the procedure from figure 6.8.
Figure 6.10 [Go] Button
Rev. 1.00 Nov. 26, 2007 Page 159 of 230
Section 6 Tutorial
REJ10J1766-0100

Advertisement

loading

This manual is also suitable for:

Superh e10a-usb