Section 5 Debugging
[End]:
[Set]:
[New]:
[Result] button: Obtains the result of statistical information analysis.
[Clear]:
[Result] list box: Displays all conditions and results of statistical information analysis.
[Close]:
This dialog box allows the user to analyze statistical information concerning the trace information.
Set the target of analysis in [Item] and the input value or character string by [Start] and [End].
Click the [Result] button after setting a condition by pressing the [New] or [Add] button to
analyze the statistical information and display its result in the [Result] list.
Note: In this emulator, only [PTR] can be set as a range. Each of other items must be specified
as a character string. In analysis of statistical information, character strings are compared
with those displayed in the [Trace] window. Only those that completely match are
counted. Note, however, that this test is not case sensitive. The number of blanks will not
be cared either.
Rev. 1.00 Nov. 26, 2007 Page 140 of 230
REJ10J1766-0100
Specify the end value if a range has been set (only available when
[Range] has been selected).
Adds a new condition to the current one.
Creates a new condition.
Initializes the settings.
Closes this dialog box. All the results displayed in the [Result] list will
be cleared.