Download Print this page

Renesas HS0005KCU04HE User Manual page 103

Multi-core emulator

Advertisement

[Synchronization options]
Notes:
1. Includes the interrupts during a break.
2.
When one of the CPU transfers to the deep standby mode and the [Software standby
mode] during execution of the user program, the emulator can not access the memory
and can not perform a break. To keep performing the emulator, after releasing the
[Deep standby mode] and the [Software standby mode], operate the emulator or
replace the deep standby mode and the software standby mode to sleep mode by
selecting the [Sleep mode] in this emulator.
3.
To perform the synchronized execution, after the setting of [Go] options, clicking on
the [Execution] button or the command line in each of High-performance Embedded
Workshop for CPU0 and CPU1 is needed. When both of the High-performance
Embedded Workshop became the executed mode, the synchronized execution for the
actual user program will be started.
4.
When setting the synchronized stepping, the synchronized execution and the
synchronized break will be set on a mandatory. To perform the synchronized stepping,
after setting the [Step] options from the [Synchronization options], in either CPU0 or
CPU1 of the High-performance Embedded Workshop, at first, click on the [Step In]
([Step Over] or [Step Out]) button or the command line in the each of High-
performance Embedded Workshop for CPU0 or CPU1. Next, to execute the user
program by clicking on the [Execute] or the [Step In] button are needed. When the
both of the High-performance Embedded Workshop became the execution mode, the
synchronized [Step In] ([Step Over] or [Step Out]) for the actual user program will be
started.
Sleep:
Specifies transitions to sleep mode.
Specify the operation of synchronized execution.
Go:
Step:
Break:
Section 5 Debugging
Execution is synchronized.
this condition is modified, all of the
PC break points will be erased.
Stepping is synchronized.
condition is modified, all of the PC
break points will be erased.
Breaks are synchronized.
condition is modified, all of the PC
break points or event points will be
erased.
Rev. 1.00 Nov. 26, 2007 Page 83 of 230
*2
*3
When
*4
When this
*5
When this
REJ10J1766-0100

Advertisement

loading

This manual is also suitable for: