Multi-core emulator

Advertisement

Set filtering conditions and then press the [OK] button. This starts filtering according to the
conditions. Clicking the [Cancel] button closes the [Trace Filter] dialog box, which holds the
settings at the time when the dialog box was opened.
In filtering, only the trace information that satisfies one or more filtering conditions set in the
above pages will be displayed in the [Trace] window.
Filtering conditions can be changed several times to analyze data because the content of the trace
buffer is not changed by filtering.
(1) [General] page
Set the range for filtering.
Figure 5.29 [Trace Filter] Dialog Box ([General] Page)
[Don't care other pages]: Only selects the cycle number when this box is checked. Other options
[Enable Filter]:
[Not designation]:
[Trace display range]:
become invalid.
Enables the filter when this box is checked.
Filters information that does not match the conditions set in those pages
when this box is checked.
Sets the range for filtering.
Section 5 Debugging
Rev. 1.00 Nov. 26, 2007 Page 133 of 230
REJ10J1766-0100