3 Maintenance

3.2.1 Maintenance schedule

3.2 Maintenance schedule and component life

3.2.1 Maintenance schedule
General
The DressPack must be maintained regularly to ensure its function. The lifetime
of a process cable package can be extended with the correct preventive
maintenance activities. A daily visual check of the DressPack is highly
recommended, which is normally performed by robot production personnel. It is
essential that the person performing the visual check have basic training in ABB
DressPack.
Wear parts
Wear parts should be replaced before considerable damage occurs to the process
cable package. Replace wear parts before the part is completely damaged.
The following parts are considered as wear parts:
Activities and intervals, standard equipment
The sections referred to in the table can be found in the different chapters for each
maintenance activity.
The table below specifies the required maintenance activities and intervals:
Maintenance
activity
Inspection
Inspection
Inspection
Cleaning
Cleaning
i
DressPack upper arm cable package
Based on experience, some parts are more exposed to wear. Therefore the
DressPack upper arm cable package should be inspected according to the following
schedule.
Interval
Weekly
Every two weeks
Continues on next page
152
Protection sleeves
Protective hose
Equipment
Water & Air unit
All cables
DressPack upper arm
DressPack upper arm
Water & Air unit
"Regularly" implies that the activity is to be performed regularly, but the actual interval may not be
specified by the robot manufacturer. The interval depends on the operation cycle of the robot, its
working environment and movement pattern.
Generally, the more contaminated the environment, the closer the maintenance intervals. Also, the
more demanding the movement pattern (sharper bending cable harness), the closer the intervals.
© Copyright 2014-2017 ABB. All rights reserved.
Interval
Detailed in section:
1 month
i
Regularly
Preventive inspection of all
cables, DressPack on page 154
Regularly i
Preventive inspection,
DressPack upper arm on
page 156
Regularly i
Cleaning, DressPack upper
arm on page 162
Regularly i
Action
None
Inspection wear
Product manual - DressPack/SpotPack IRB 6700
3HAC044270-001 Revision: F