4 Repair
4.2.5 Replacing the protection hose IRBDP SW6 UI and IRBDP MH6 UI
Continued
2
3
4
5
Continues on next page
190
Action
Remove the cable and hose retainer.
Remove the hose clamps (2 pcs) securing
the hose reinforcement funnel.
Remove the hose reinforcement funnel (two
parts).
Note
Pull carefully out cables and hoses and re-
move the front part of the protection hose.
© Copyright 2014-2017 ABB. All rights reserved.
Note
xx1200000103
xx1400000209
xx1400000210
Best performed in this order:
1 Cables with the smallets connectors
2 Hoses
3 Cables with the biggest connectors.