8
9
10
Product manual - DressPack/SpotPack IRB 6700
3HAC044270-001 Revision: F
4.2.3 Replacing the cable package IRBDP SW6 LE (Lean ID)
Action
Carefully pull out the cable package
through the hole in the base.
This is best done following this order:
1: Hoses
2: Weld cables
3: Remaining cables
Disconnect connectors of the cable pack-
age IRBDP SW6 UI on the connection plate.
Note
Do not disconnect the connectors of the
cable package IRBDP SW6 LE. The connec-
tion plate is part of IRBDP SW6 LE.
Unscrew the attachment screws that holds
the connection plate.
© Copyright 2014-2017 ABB. All rights reserved.
Note
xx1400000213
xx1400000214
xx1400000194
Continues on next page