ABB DressPack IRB 6700 Product Manual page 196

Hide thumbs Also See for DressPack IRB 6700:
Table of Contents

Advertisement

4 Repair
4.2.5 Replacing the protection hose IRBDP SW6 UI and IRBDP MH6 UI
Continued
6
7
Step 3 - Cable and hose retainer (wrist)
1
Continues on next page
196
Action
Secure the hose reinforcement funnel with
the hose clamps.
Check that the screws on the hose clamps
are fitted in the correct position.
Action
Arrange cable and hoses according to their
position in the cable and hose retainer.
© Copyright 2014-2017 ABB. All rights reserved.
Note
xx1400000209
xx1400000222
Note
PROC 4
SP
CPS
WELD EARTH
WELD V
xx1200000106
Note
This is an example showing the Paracom
cable harness. If in doubt check the posi-
tions on a cable and hose retainer that still
is fitted.
Product manual - DressPack/SpotPack IRB 6700
3HAC044270-001 Revision: F
PROC 3
PROC 2
FB7
PROC 1
WELD U

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spotpack irb 6700

Table of Contents