4 Repair
4.3.2 Replacement of Water-in circuit
Continued
Removal
The procedure below details how to remove the water-in circuit. It does not deal
with details specific to each version, such as article numbers, connector types etc.
For details see the Spare parts section.
1
2
3
4
5
6
7
8
Refitting
The procedure below details how to refit the water-in circuit. It does not deal with
details specific to each version, such as article numbers, connector types etc. For
details see the Spare parts section.
1
2
3
4
5
6
7
8
202
Action
Turn off the water supply to the Water and Air unit.
Remove the hose of the water supply of the work-
shop to the Water-in circuit.
Remove the Proc 2 hose from the Water and Air
unit.
Remove the Pushlok nipple.
Loosen the locking nut.
Unscrew the two attachment screws holding the
water-in circuit.
Remove the Water-in circuit from the mounting
plate.
Remove the DIN-connector from the electrical water
valve.
Action
Attach the DIN-connector to the electrical water
valve.
Fit the water-in circuit with its two attachment
screws on the mounting plate.
Tighten the locking nut.
Fit the Pushlok nipple.
Connect the Proc 2 hose on the Water and Air unit.
CAUTION
Do not tighten the brass couplings for water and air
with excessive force.
Connect the hose of the workshop water supply to
the Water-in circuit.
Turn on the water supply to the Water and Air unit.
Check for leakages.
© Copyright 2014-2017 ABB. All rights reserved.
Note
Note
Tightening torque, brass coup-
lings 1/2": 31 Nm
Tighten if there are any leaks.