Fuel System Bleeding - New Holland B95CTC Operator's Manual

Hide thumbs Also See for B95CTC:
Table of Contents

Advertisement

Fuel system bleeding

NOTE: do not loosen any fuel lines or injector lines to bleed
air from the system. They are under high pressure and
therefore their loosening is dangerous.
From the bottom of the filter, remove the connector (3).
Place a container under the prefilter.
Open bleed screw (1) on prefilter only and activate hand
primer (2) until fuel flows freely from the bleed screw.
This generally takes 35-45 pumps to fill the fuel lines and
the prefilter.
This can be done in about 30 s.
Tighten bleed screw.
Dry with cloth the prefilter.
Connect the electric connector under the prefilter.
Start the engine. Engine should start within 5 s.
Lower and lock the engine tilt hood.
Remove the safety support strut and lower the loader at-
tachment.
7 - MAINTENANCE
7 - 53
1
LEEN12T0685AA
2
LEEN11T0355AA
3
LEEN11T0370AA