7A-144 Heating, Ventilation and Air Conditioning:
Air Temperature Door Replacement - Auxiliary
Callout
Preliminary Procedure
1. Remove the auxiliary HVAC module. Refer to "Auxiliary HVAC Module Replacement"
2. Disconnect electrical connections.
3. Remove lower HVAC case screws.
Refer to 07 193 Aux. EVAP Replacement
Tip: The HVAC lower and side cases must be separated for temperature door removal.
Auxiliary HVAC Side Case Screws
CAUTION
!
1
Refer to "Fastener Notice: ".
Tightening torque
1.5 N⋅m (13 lb in)
Auxiliary Temperature Door
Tip:
2
• Ensure evaporator gasket is in good condition upon installation.
• Ensure temperature and mix doors are in proper position upon assembly of side cases.
Component Name