7A-96 Heating, Ventilation and Air Conditioning:
13. Remove the bolt retaining the liquid line to the body.
14. Position the battery box inboard to allow for routing
of the liquid line.
15. Route the liquid line above the battery box and the
ground lug.
16. Lift the rear portion of the liquid line upward and
remove the liquid line from the vehicle.
17. Remove and discard the sealing washer from the
liquid line. Refer to "Sealing Washer Replacement".
18. Install protective caps to the condenser, the
evaporator outlet hose, and the TXV to prevent
contamination and desiccant saturation.
Installation Procedure
1. Route the liquid line below the battery box and the
ground lug.
CAUTION
!
Refer to "Fastener Notice: ".
2. Connect the negative battery cable nut to the
wheelhouse.
Tightening torque
Tighten the nut to 12 N⋅m (106 lb in).
3. Remove the protective caps from the condenser, the
evaporator outlet hose, and the TXV.
4. Install the new sealing washer to the liquid line.
Refer to "Sealing Washer Replacement".
5. Route the condenser end of the liquid line into
position.
6. Install the liquid line to the condenser.

Advertisement