Suzuki XL7 2007 Service Manual page 1889

Jc636
Hide thumbs Also See for XL7 2007:
Table of Contents

Advertisement

A/C Performance Table
Ambient
Temperature
13-18°C (55-65°F)
19-24°C (66-75°F)
25-29°C (76-85°F)
30-35°C (86-95°F)
36-41°C (96-105°F)
42-46°C (106-115°F)
47-49°C (116-120°F)
Air Conditioning (A/C) Diagnostics - Pressure Zone A
Step
DEFINITION: The high and low side pressures may be normal or slightly less than normal.
• Air Delivery Concern
• Slight Refrigerant Under Charge
• Refrigerant Contamination
Were you sent here from the air conditioning (A/C)
System Performance Test?
1
Refer to the instrument panel outlet air temperatures
recorded during the A/C system performance test.
2
Does the discharge air temperature between the right
and left center instrument panel outlets vary by more
than 1-2°C (2-3°F)?
Did the customer mention that the A/C system output
3
temperatures are good at first, but then turn warm
during extended drives?
Low Side Service
Relative Humidity
130-296 kPa (19-43
0-100%
144-303 kPa (21-44
Below 40%
151-303 kPa (22-44
Above 40%
151-303 kPa (22-44
Below 35%
179-282 kPa (26-41
35-60%
179-282 kPa (26-41
Above 50%
179-268 kPa (26-39
Below 30%
179-282 kPa (26-41
30-50%
179-275 kPa (26-
Above 50%
213-310 kPa (31-45
Below 20%
213-310 kPa (31-45
20-40%
206-310 kPa (30-45
Above 40%
234-337 kPa (34-49
Below 20%
241-344 kPa (35-50
Above 20%
254-351 kPa (37-51
Below 30%
Action
Heating, Ventilation and Air Conditioning:
High Side Service
Port Pressure
Port Pressure
876-1412 kPa (127-
psi)
1129-1639 kPa (164-
psi)
1205-1688 kPa (175-
psi)
1334-1846 kPa (198-
psi)
1646-1922 kPa (239-
psi)
1667-1908 kPa (242-
psi)
1446-1701 kPa (210-
psi)
1481-1694 kPa (215-
psi)
1416-1653 kPa (206-
40psi)
1660-1887 kPa (241-
psi)
1653-1908 kPa (240-
psi)
1626-1853 kPa (236-
psi)
1825-2053 kPa (265-
psi)
1798-2046 kPa (261-
psi)
2004-2246 kPa (291-
psi)
Value
Maximum Left
Center Discharge Air
Temperature
8°C (46°F)
205 psi)
12°C (52°F)
238 psi)
03°C (50°F)
245 psi)
13°C (54°F)
268 psi)
13°C (54°F)
279 psi)
12°C (52°F)
277 psi)
14°C (57°F)
247 psi)
14°C (57°F)
246 psi)
13°C (55°F)
240 psi)
15°C (59°F)
274 psi)
15°C (59°F)
277 psi)
15°C (59°F)
269 psi)
18°C (63°F)
298 psi)
18°C (63°F)
297 psi)
18°C (64°F)
326 psi)
Yes
Conditioning (A/
Performance
Go to Step 2
Test (w/ C69)"
"Air Conditioning
(A/C) System
Performance
Test (w/o C69)"
Go to Step 7
Go to Step 3
Go to Step 4
Go to Step 5
7A-75
No
Go to "Air
C) System

Advertisement

Table of Contents
loading

Table of Contents