PI-BD (Processor Interface Circuit Pack)
Table 10-458. PI-BD Error Log Entries — Continued
Error
Aux
Code
Data
1025 (i)
4363
NPE Audit Test (#50)
1538 (j)
Any
None
3585 (d)
Any
None Test (#423)
3840 (i)
Any
None
3841
Any
Standby PI Circuit Pack
Test (#423)
3999(k)
Any
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
!
WARNING:
The "test interface long" command resets the PI-BD and cause all ISDN-PRI
and BX.25 links to come down.
Notes:
a. Indicates the circuit pack totally stopped functioning or it was physically
removed from the system.
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. Or, if the circuit pack is in the
system and the red LED is on, then replace the circuit pack.
!
If this is a Duplicated Option system, verify that there is an equal number of
Processor Interface circuit packs in each SPE complex. If there is not an
equal number of Processor Interface circuit packs, this condition could
cause alarms on the STBY-SPE, DUPINT, SHDW-CIR, as well as the
PI-BD.
555-233-123
Associated Test
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
CAUTION:
Reseating the circuit pack may cause a system restart if the circuit
pack is located on an Active SPE complex.
On/
Alarm
Off
Level
Board
test interface PCS sh
MINOR
ON
MAJOR
ON
reset interface PCS l
MAJOR
ON
test interface PCS sh
Continued on next page
Issue 4 May 2002
Test to Clear Value
10-1225