180788-1CD
MPX2600

4.2.4 Intrinsically Safe Cable Connection

Fig. 4-9: Connection of Intrinsically Safe Terminal Block of the Pressure Switch Unit and Barrier
1) Intrinsically safe cable
1 Cable type (applied):
CVV-S, 1.25 mm² (2, 4, 6, 8, 10, 12 cores),
CVV-SB, 1.25 mm² (2, 4, 6, 8, 10, 12 cores), or
UL2586-SB, 1.25 mm² (2, 4, 6, 8, 10, 12 cores)
(SUMIDEN HITACHI CABLE Ltd.)
- The cable to be connected with terminal blocks
P1 to N3, and 1 to 2 are different.
- P1 to N3 and 1 to 2 are separated by the shield.
2 Cable connection
Intrinsically safe
terminal block
on the pressure
switch unit side
P1
N1
P2
N2
P3
N3
1
2
Note) The barriers between P2 and N2 in the DX200 are
short-circuited by the wire.
Do not remove the wire.
On the manipulator side, however, since a short-circuit
does not exist, there is no wire.
Also, no wiring exists on each manipulator side and
the DX200 side between P2 and between N2.
2) Pressure switch unit side : Crimped terminals
For connecting the intrinsically safe
cable to the intrinsically safe terminal block
- For terminal block P1 to 2
3.5 min
3.7 dia. min
4
Wiring
4.2 Cable Connection
DX200
P1
N1
P2
N2
P3
N3
1
2
4 max
4-13
3) Controller side: Crimped terminals
For connecting the intrinsically safe cable
to the relay barrier in the DX200
- For terminal block P1 to N3
5.3 min
3.2 dia. min
For connecting the intrinsically safe cable
to the insulation barrier in the DX200
- For terminal block 1 to 2
10
1.25AF2.3B(JST Made)
(Recommended terminal)
The intrinsically safe device connected to the relay
barrier must satisfy the following conditions.
Intrinsically
safe circuit: Pressure detection / flow switch circuit
Allowable voltage: 13.2 V
Allowable current: 14.2 mA
Allowable electric power: 46.9 mW
Internal inductance: 32.9 μH
Internal capacitance: 32.6 nF
HW1484370