YASKAWA MOTOMAN-MPX2600 Instructions Manual page 9

Table of Contents

Advertisement

180788-1CD
MPX2600
YASKAWA ELECTRIC CORPORATION
2-1 Kurosakishiroishi, Yahatanishi-ku
Kitakyushu 806-0004 Japan
YR-MPX2600-C00
II2G
II(2)G
Serial No:
Year of Manufacture :
Maximum Voltage :
Maximum Current :
Maximum Capacity :
Maximum Power :
Ambient Temperature
Manipulator :
Painting Unit :
Intrinsically Safe Circuitry
Battery Back Up Circuitry :
{Lithium/Iron Disulfide Battery (ENERGIZER L91)}
Non-Intrinsic safety circuit
Allowable Voltage :
Minimum Dilution Flow Rate :
Setting Pressure for Purging :
Minimum Purge Flow Time :
Minimum Flow Rate of Protective Gas:
Maximum Leakage :
Minimum Over Pressure(input) :
Maximum Over Pressure(input) :
Setting Pressure for Operating :
Protective Gas Temperature :
Pressurization System
Minimum Line Pressure :
Maximum Line Pressure :
Routine Test :
WARNINGS:
1.
Do not make any changes of the equipments and wiring in the manipulator,
relay barrier,isolated barrier and encoder separation board (inside the painting unit)
and combination equipment of Internal pressure explosion-proof structure.
2.
Battery backup circuit is consisted of battery unit, position detector
and encoder separation board. The circuit is intrinsically safe circuit
when the power supply of the Controller is shut down or air purging.
3.
The painting Unit combined shall be grounded at 100 ohms or less.
4.
Relay barrier, isolated barrier and encoder
separation board (inside the painting Unit) shall be installed in a non-hazardous area.
5.
Pressurized enclosure, do not open when energized.
Enclosure contains lithium battery.
6.
Do not open when an explosive atmosphere is present.
7.
This is pressurized enclosure.
8.
Refer to instructions in the manual before opening.
9.
Remove all dust from this enclosure before connecting
or restoring the electrical supply.
Explosion-Proof Indication Label and Warning
Fig. : Explosion-Proof Indication Label (ATEX)
CML 17ATEX1034X
Ex ib pxb B T4 Gb/Ex ib B T4 Gb
Manipulator
Painting Unit
[Ex ib Gb]
3Px200V (-15%,+10%)50/60Hz
3Px220V (-15%,+10%)60Hz
8.7
9.9
3.0
0°C to +40°C
0°C to +45°C
DC4.5V 37.9mA
AC250V 50/60Hz,DC250V
320 L/min
0.18 to 0.20 MPa
4 min
15 NL/min
15 NL/min
5 kPa
50 kPa
0.01 to 0.02 MPa
0°C to +40°C
0.35 MPa
0.65 MPa
Pass
Note 1
2503
B
A
KW
KVA
DWG.No,
NJ
HW1484370
ix
Notified Body Number
Certificate Number
Note 1
The place of production
may be replaced with the
following address it is the
ATEX-approved one.
YASKAWA Europe GmbH
Yaskawastr.1, D-85391
Allershausen Germany
9 of 116

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents