Stopping Distance And Time For S-, L-, And U-Axes; General Information; Definition Of Use; Stopping Distance And Time For Stop Category 0: S-, L- And U-Axes - YASKAWA MOTOMAN-MPX2600 Instructions Manual

Table of Contents

Advertisement

MPX2600
5.6

5.6.1 General Information

5.6.2 Definition of Use

5.6.3 Stopping Distance and Time for Stop Category 0: S-, L- and U-Axes

5
Basic Specifications

5.6 Stopping Distance and Time for S-, L-, and U-Axes

Stopping Distance and Time for S-, L-, and U-Axes
• The stopping distance is an angle traveled by the manipulator from
the moment when the stop signal is activated until the manipulator
comes to a complete standstill.
• The stopping time is a time elapsed from the moment that the stop
signal is activated until the manipulator comes to a complete
standstill.
• The data that are given for the main axes S, L and U are the
maximum displacement.
• Superposed axes motions may result in longer stopping distance.
• Stopping distance and stopping time are measured in accordance
with ISO 10218-1, Annex B
• Stop categories: According to IEC60204-1
• Stop category 0
• Stop category 1
• The values specified for Stop category 0 are the reference values
that are determined by tests and simulations. The actual stopping
distance and stopping time may differ.
Load:
Rated load weight and load on an arm
Speed:
Operating speed of the manipulator
Extension: Distance between the rotation center and the P-point of
each axis
Measurement Conditions
• Load:
Maximum load
• Speed:
Maximum speed
• Posture: Maximum inertia generation posture
Axis
Stopping distance (deg)
S-axis
17.1
L-axis
22.6
U-axis
14.7
5-6
180788-1CD
Stopping Time (sec)
0.230
0.317
0.189
HW1484370
62 of 116