4.4
System Components
Manipulator (explosion-proof)
DX200
(not explosion-proof)
Pressure Switch unit
(explosion-proof)
Programming pendant
(not explosion-proof)
Programming pendant (explosion-
proof) (Optional)
4
Wiring

4.4 Installation Site

Installation Site
This section describes the conditions of the installation site for the robot
system. Only devices that are approved as explosion-proof can be
installed in hazardous locations. Refer to the local regulations and safety
codes for the definition of a hazardous location. Install the controller and
control panels in a location free from water drops, dust, and dirt.
Hazardous
Location
(Inside Painting
Booth)
×
×
In case installing the MOTOMAN-MPX2600 in the hazardous area,
classify the manipulator environment by following the local
explosion-proof standard and then, on the basis of the explosion-
proof structure notation on the MOTOMAN-MPX2600, confirm that
the manipulator is possible to install in that area.
Devices that are not explosion-proof must not be installed in hazardous
locations. Failure to observe this warning may result in a fire.
4-16
Non-hazardous
Ambient
location
Temperature
(Outside Painting
Booth)
0 to 40 °C
0 to 45 °C
×
0 to 40°C
0 to 40 °C
0 to 40 °C
DANGER
WARNING
HW1484370
180788-1CD
Maximum
Ambient
Humidity
80%RH
90%RH
85%RH
85%RH
85%RH