MPX2600
4.3
Table 4-3: Specifications
No.
Item
1
Power supply
2
Air supply
Pressurized
explosion-proof
construction
3
Grounding
4
Wiring

4.3 Requirements

Requirements
Prepare the power supply, the air supply, and the grounding according to
the following specifications.
Specifications
3-phase 200/220 VAC
(Voltage: +10 to -15%)
50/60 Hz (±2 Hz)
3.0 kVA (at peak)
Required pressure: 0.35 MPa to 0.65 MPa
Capacity:
For pressurized type of explosion
protected construction
At operating: 15 NI/min or more
At purging: 1000 Nl/min or more
Dryness: Freezing at -18 °C
Grounding resistance: 100 Ω or less
Use dry air for the pressurized explosion-proof enclosure. Moisture in
the air supply may damage the electronic parts.
4-14
Remarks
Use dry air for the
pressurized explosion-proof
construction.
For the DX200
CAUTION
HW1484370
180788-1CD
54 of 116