Henny Penny 500 Service Manual page 98

Pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

el
50
17. Connect the wires to the new thermostat.
Be careful not to cross the wires or thermostat will
not operate properly.
18. Uncoil the capillary tube.
19. Insert the bulb through the wall of the frypot.
To avoid electrical shock or other injury the
capillary line must run under and away from all
electrical power wires. The tube must never be in
contact with the electrical power wires or termi-
nals; electric shock could result.
20. Install the thermostat pot fitting into the wall of
the frypot and tighten.
21. Replace the thermostat
sensing bulb into the
mounting bracket.
Do not bend the capillary tube where it connects
to the sensing bulb, or damage to capillary will
result.
22. ELECTRIC only: slip the bulb holder in place. With
bulb in place, tighten the clamp screw.
23. Pull the excess capillary tube from the inside of the
frypot.
24. Insert and tighten the inside screw nut into the
thermostat pot fitting.
25. Install the two screws on the front of the control
panel which secure the thermostat to the back of
the panel. Install the thermostat bezel.
nstall the thermostat knob.
27. Install the control
which hold the to
1 over the metal flanges
panel in place.