Step
4
14.
rain the vinegar rinse water and discard.
inse down the frypot, using clean hot water.
16. Thoroughly dry the drain pan, and the frypot inter-
ior.
Make sure the inside of the frypot, the drain
valve opening, and all the parts that will come in
contact with the new shortening are as dry as
possible.
17. Replace the clean filter assembly in the drain pan
and install under fryer.
18. Refill the fryer with fresh shortening.
At the end of each day, the operating valve must be
cleaned as follows:
1. Turn the main power switch off. Be sure all pres-
sure has been released and open the lid.
2. Unscrew the valve cap and remove the cap and
weight.
Use gloves. Valve cap may be hot. Burns could
result.
3. Clean the cap and weight in hot detergent water.
Make certain to thoroughly clean the inside of the
valve cap and the weight.
4. Clean the exhaust tube with stainless steel brush
enny Penny part number 12147).