3. When the red arrow reaches"50":
A buzzer will sound.
The timer indicator light will go off.
You will once again hear the metallic "click"
sound from the solenoid valve. This will indicate
it has de-energized and is in the "open" position.
4. Move the timer switch to the OFF position.
The buzzer will stop.
The red arrow will return to the original present
time - in this case three (3) minutes.
1. Open the front door of the fryer.
2. Loosen the filter union connection (item 28, figure
3-l).
urn the main power switch to the PUMP position.
Open the filter valve. You will hear the electric
motor running.
I
Only run the pump for a few seconds.
4. Place your thumb over the open filter union flare.
You should feel suction. Close the filter valve. Turn
off the pump.
The electric motor bearings are permanently
lubri-
0 NOT LUBRICATE.
This completes the testing cycle. If any of the functions
did not occur, recheck the installation.
If a problem
persists, refer to other sections of this manual or call an
enny Penny distributor.