el 5
I56
HEATING ELEMENTS
HIGH LIMIT
CAPILLARY TUBE
emove the two electrical wires from the high
temperature limit control.
4. Check for continuity between the two terminals after
resetting the control. If the circuit is open, replace
the control, then continue with this procedure. (If the
circuit is closed, the high limit is not defective. Recon-
nect the two electrical wires.)
efore follow
UMP switch to the OFF position, and
the power cord or open the wall circuit
breaker, or electrical shock could result.
1. If the tube is broken or cracked, the control will open,
shutting off electrical power. The control cannot be
reset.
2. Drain shortening from the frypot.
emove control panel.
osen small inside screw nut on capillary tube.
move capillary bulb from bulb holder inside the
frypot.
6. Straighten the capillary tube.
emove larger outside nut that threads into pot wall.
emove the two screws the secure the high limit to
the high limit bracket.
emove defective control from control panel area.
sert new control and replace screws.
11. Uncoil capillary line, starting at capillary tube, and
insert through frypot wall.
To avoid electrical shock or other injury, the capillary
line must run under and away from all electircal power
wires and terminals. The tube must never be in such
a position where it could accidentally touch the
electrical power terminals.
12. Carefully bend the capillary bulb and tube toward
bulb holder on heating elements.
ulb into bulb holder located on heating
11 excess capillary line from pot and
tighten nut into frypot wall.