Henny Penny 500 Service Manual page 5

Pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

Nominal Heat Input:
(Net)
Natural (I,,) = 2 1,l KW
(72,000 Btu/h)
Liquid Propane (I& = 2 1,l KW (72,000 Btu/h)
Nominal Heat Input:
Natural (I& = 23,4 KW
(80,000 Btu/h)
(Gross)
Liquid Propane (I,,) = 23,4 KW (80,000 Btwh)
Supply Pressure:
Natural (I& = 20 mbar
Liquid Propane (I,,) = 37 mbar
Test Point Pressure:
Natural (I,,) = 8,7 mbar
Liquid Propane (I,,) = 25 mbar
Injector Size:
Natural (I,,) = 0,66 mm
Liquid Propane (I,,) = 1,04 mm
This appliance must be installed in accordance with the manufacturers instructions and the
regulations in force and only used in a suitable ventilated location. Read the instructions fully
before installing or using the appliance.
atos ~e~nicQs
Consumo Caloric0 Nominal:
(Net4
Gas Natural (I& = 21 ,l KW (72,000 Btu/h)
Propano Licuado (IJ = 21,l KW (72,000 Btu/h)
Consumo Caloric0 Nominal:
(Bruto)
Gas Natural (I,,) = 21,l KW
(80,000 Btu/h)
Propano Licuado (I,,) = 21,l KW
(80,000 Btu/h)
Presion De Alimentacion:
Gas Natural (I& = 20 mbar
Propano Licuado (IJ = 37 mbar
Presion En Ez Punto De Prueba: Gas Natural (I,,) = 8,7 mbar
Propano Licuado (IJ = 25 mbar
Diiunetro Boquilla:
Gas Natural (I,,) = 0,66 mm
Propano Licuado (I,,) = 1,04 mm
Este equip0 debe instalarse kkxmente en un recinto adecuadameute ventilado y conforme a las
indicaciones de1 fabricante y a las normas vigentes. Lea completamente las instrucciones antes
de instalar o usar este equipo.