18. After the main timer has run for 2 minutes, turn the
thermostat to the high setting used.
19. The fryer should now recover to the low setting.
Once again, with a thermometer,
check the
temperature at which the heat light goes off.
20. If the low setting is too high or too low, remove the
thermostat knob and place a small screwdriver in the
hole at the 11 o'clock position on the white calibra-
tion plate. Each
l/2
turn equals 25 degrees. By turn-
ing the adjusting screw clockwise, the low setting is
decreased.
By turning
the adjusting
screw
counterclockwise, the low setting is increased.