Henny Penny 500 Service Manual page 81

Pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

odel
1
paragraph 5-10. Replace
thermostat if found to be faulty.
Incorrect jet size.
0 Replace with proper size jet for
type of gas, and altitude (contact
@ Improper ventilation
system.
0 Refer to paragraph 2-6,
Possible faulty thermostat.
@ Calibrate thermostat per
Foaming or boiling
over of shortening
(Gas/Electric
odels)
Water in shortening.
Condensation line stopped up.
Improper or bad shortening.
Improper filtering.
Improper rinsing after
cleaning the fryer.
0 At end of frying cycle, drain
shortening and clean frypot.
Add fresh shortening, and check
procedure for raising lid.
emove and clean condensation
line.
Use recommended shortening.
Refer to the procedure covering
filtering the shortening.
Clean and neutralize the frypot.
Rinse with vinegar to remove
the alkaline then rinse with hot
water, and dry frypot.

Advertisement

Table of Contents
loading

This manual is also suitable for:

561600

Table of Contents