emove control panel and install it in the slot
above the door.
20. Connect the gas valve wires to the thermostat and
high temperature limit control as labeled.
21. Install control panel per paragraph 5-4.
22. Uncap and reconnect the main gas supply line to
the fryer. Turn on the main gas supply.
Check for leaks per paragraph 2-9. Leaking gas
may cause an explosion.
23. Connect the service cord to the wall receptacle, or
close circuit breakers.
24.
light the gas pilot per the instructions in para-
graph 2-11.
he thermocouple controls the gas valve. It generates
voltage in the millivolt.
This voltage signals the gas
control valve to remain open to the pilot and burner.
en the voltage is not generated the gas valve will
shut off, not allowing gas to the pilot and main burner.
If converting from natural'gas to propane gas or
from propane gas to natural gas, conversion must
be done by a qualified technician.
To avoid injury or prope~y damage, before start-