is procedure move MAIN
0 OFF position.
main circuit breaker at the main circuit breaker
box and unplug service cord from wall receptacle,
or electrical shock could result.
To convert from one type of gas to another the follow-
ing procedure may be followed:
1. Turn the gas cock dial to the OFF position.
2. Close the main gas valve and disconnect fryer supply
line.
efer to figure 6-21 and remove gas control valve
and burner assembly per paragraph 5-16.
emove the burner orifices (24 each), and replace
with orifices in gas conversion kit 16247 - natural to
propane conversion or kit 16248 - propane to natural
conversion kit.
emove the pilot orifice and replace with the one
from the kit being installed.
emove the two screws securing the gas valve
regulator, and remove regulator and diaphram, and
replace with each from the kit being installed, per
paragraph 5-18.
7. Install converted gas control valve and burner
assembly per paragraph 5-16.
8. Connect the gas supply to the fryer.
. nsure the power switch is in the
osition, gas
control valve in the
position.
10. Connect the electrical power to the fryer.

Advertisement