Henny Penny 500 Service Manual page 22

Pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

The gas regulator is preset at the factory at 3.5 inch
water column for natural gas (10.0 inch for propane). If
adjustment is necessary, refer to paragraph 5-18.
The electric fryer is available from the factory wired for
208,220/240, or 440/480 volts, single or three phase, 60
Hertz service. The proper power service cable must be
ordered as an accessory or provided at installation.
Check the data plate on the inside of the fryer door to
determine the correct power supply.
This fryer
must be adequately
and safely
grounded. Refer to local electrical codes for cor-
rect grounding
procedures.
If fryer
is not
adequately grounded, electrical shock could re-
sult *
A separate disconnect switch with proper capacity fuses
or breakers must be installed at a convenient location
between the fryer and the power source. (The field sup-
ply wiring to the fryer should be of the size indicated in
the data table.) It should be an insulated copper conduc-
tor rated for 600 volts and 90°C. For runs longer than 50
feet, use the next larger size wire.
Table
using for Electric
Fryer
V&s
Phase
KW
SUPPlY
Min.
Wire
Fuse
Amps
Size
Size
208
208
208
208
2201240
2201240
2201240
2201240
4401480
4401480
Single
Single
Three
Three
Single
Single
Three
Three
Three
Three
13.50
11.25
13.50
11.25
13.50
11.25
13.50
11.25
13.50
54
4
65
2
31
8
38
6
51156
414
56161
413
30132
818
33135
616
13114
12112
18116
12112
70
90
40
50
70170
70180
40140
50150
20120
20120