PRIMARY CONTACTf
IR
HEAT CONTACTOR
3.
n fryers using three phase power, check voltage
as follows:
Test Points
eat contactor
from terminal 34 to 35
from terminal 35 to 36
from terminal 34 to 36
Primary contactor
from terminal 27 to 28
from terminal 28 to 29
from terminal 27 to 29
The voltage
should read
the same at
each terminal.
It should
correspond to
the voltage
rating stated
on the data
plate.
If either contactor is defective it must be replaced as
follows:
Remove electrical power supplied to the fryer, by
unplugging or opening the wall circuit breaker, or
electrical shock could result.
1. Remove only those wires directly connected to the
contactor being replaced. Label the wires.
emove the two mounting screws on the base plate
and remove contactor.
3. Install the new contactor and tighten the two mount-
ing screws.
4. Connect the labeled wires to their respective
positions.
I
5. Install the control panel per paragraph 5-4.
econnect power to the fryer and test the fryer for
proper operation.