Henny Penny 500 Service Manual page 24

Pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

el 5
1561
ny
Y
tep 1
step 2
1.
lace a cool, damp cloth on the heating elements.
2.
ith the lid open, momentarily turn the thermos-
tat to a setting of 200°F.
o not leave the thermostat on for more than 10
seconds whenever the elements are not covered
with shortening or the elements might be dam-
aged.
3. Remove the cloth and check for warmth.
4. If the cloth is warm, the heating elements are func-
tioning.
Do not touch the heating "elements with your
fingers or hands, or severe burns will result,.
5. If the heating elements are OK, clean the frypot per
section 3.
6. Fill frypot with shortening per section 3.
1. Turn the timer knob until the black arrow reaches
three minutes.
2. Move the timer switch to the ON position.
When the switch is turned on, you will hear a
metallic "click" sound from the solenoid valve
(item 24, figure 3-l). This sound tells you the
valve is energized and in the "closed" operating
position.
The timer indicator light will illuminate.
The red arrow will move toward "0".