1. Remove the gauge and check inside the pipe fittings from dead
weight body. Make certain fittings are clean and open.
I
2. Clean and reinstall the gauge.
aust
te
The dead weight valve and solenoid exhausts are directed into a
condensation exhaust tank, located in the rear of the fryer. Should
this tank become clogged, water would spew from the top of the
tank. The tank can be cleaned by running a wire or long brush from
the top of the tank, through the hole in the bottom of the tank, or
the tank can be removed to clean.
1. Remove rear cover of fryer.
When cleaning the frypot, (see section 3- 16), pour a cup of
cleaning solution into the large exhaust hose at the top of the
-exhaust
tank. This helps prevent the tank from getting clogged.
2. Pull condensation and exhaust hoses from the top and bottom
oftank.