To ensure a long life of the fryers and their components,
regular maintenance should be performed. Refer to the
chart below.
e~iQn
Daily (3-4 loads) Filter shortening
Daily
Clean dead weight valve cap,
weight, and orifice.
30
Days
Check thermostat calibration
30
Days
Lubricate spindle threads and ball
seat
90 Days
Reverse lid gasket
90 Days
Check limit stop adjustment
To replace parts inside the fryer you will often need to
remove the control panel. The following steps provide
the correct procedure:
1. Place the main power switch to the OFF position.
(This switch is labeled POWER/OFF/PUMP.)
Remove all the electrical power supplied to the
fryer by unplugging the power cord or by open-
ing the wall circuit breaker, or electrical shock
could result.
2. Remove the two screws from the bottom of the
control panel.
If the control panel has a dual indicating ther-
mostat, there are two additional screws located
at the upper left and right hand corners of the
panel.
3. Carefully slide the control panel upward until it lifts
off the metal hangers.
4. With the fryer door closed, place the lower edge of
the control panel in the slot between the door and
the frame of the fryer.
1.
o install the control panel, hook it on the metal
hangers that hold the top of the panel in place.
2. Install the two screws in the bottom of the panel.
1 ,*~
,.,.<'
i .,,.J
connect power to the fryer.