Henny Penny 500 Service Manual page 149

Pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

installation
1.
ttach the filter rinse hose with its quick discon-
nect female fitting. to the other half male fitting
inside the door, next to the filter valve handle.
2. To do this slide back the spring ring on the female
end of the quick disconnect fitting and let it snap
into place over the other half male fitting.
3. With a quick tug on the hose, insure the quick
disconnect is locked into position.
The filter valve is a % inch two-way stainless steel
ball valve. If this valve should develop leaks the entire
valve must be replaced.
Before starting
this procedure, move MAIN
POWER switch to OFF position. Disconnect main
circuit breaker at the circuit breaker box and
unplug service cord from wall receptacle, or
electrical shock could result.
1.
rain the shortening from the frypot.
2.
move the filter drain pan from the fryer.
move the cotter pin, handle, and extension rod.
emove the pipe from between the filter pump and
I
valve.
I
If fryer is equipped with optional filter rinse hose
attachment, disconnect pipe from filter valve.
~
.
Use an adjustable wrench and remove the valve.
)
eplace the valve and reassemble in reverse order.