0016
DELAY TIMER
n the optional delay timer, note timer setting
before moving dial, then check between terminals 1
and 2. The ohm reading should be:
465
1855
1677
n set timer at 1 minute and check between
terminals 6 and 7.
e circuit should be closed.
Next, set timer at zero and check between termi-
7. The circuit should be open.
set dial
to proper time setting.
1.
move electrical power supplied to the fryer.
/OFF/PUMP
switch to the OFF
lug the power cord or open the
wall circuit breaker, or electrical shock could
result.
rain the shortening from the frypot.
emove the thermostat sensing bulb from the bulb
holder inside the frypot.
4. Place your thumb at the bend in the capillary tube,
where it comes into the frypot, and straighten the
he bulb should be extending out into the
frypot.
emove the two screws which secure the control
panel to the frame of the fryer.
ift the panel up and off the metal flanges.