42 Start-up
No.
Name/Value
07
RPDO1-COB-ID
0 = Disable
1 = Default
385...1407 (dec) =
181h ... 57Fh
08
RPDO1-TR type
0...255 (dec)
Description
Defines the COB-ID for Rx PDO1.
Note: It is recommended to use the default
COB-ID.
Rx PDO1 is not valid (disabled). COB-ID is
80000200h + Node-ID.
Rx PDO1 is valid and configured to use the
default COB-ID (200h + Node-ID).
Rx PDO1 is valid and configured to use a
custom COB-ID defined with this parameter.
COB-ID must be within the allowed PDO COB-
ID range (181h - 57Fh).
Defines the Rx PDO1 transmission type. See
chapter
Appendix A – Dictionary structure and
entries
on page 161.
Rx PDO1 transmission type. See section
Description of transmission type
Default
setting
1
255
on page 162.

Advertisement