05.05
7.7.9

Structure of request/response telegrams

There is no basic difference between the useful data area in the request and response telegrams
for PROFIBUS and CAN Bus. There are differences, for example, in the protocol frame and in the
sequence in which H and L bytes are transmitted. The structures shown here are those of a
SIMOREG DC Master, i.e. the values are displayed in the same way as they would be for
parameters n733 and n735, for example. The structure of the protocol frame and the transmission
sequence of bytes are therefore described where necessary in the sections containing the start-up
description for the appropriate board.
Each request and each response basically comprises three areas apart from the telegram frame
with header and trailer:
Header
The parameter identifier (PKE) contains a request or response identifier (i.e. type of request or
response) and the number of the addressed parameter. The spontaneous signaling bit SPM (bit11)
is not used on the SIMOREG DC master.
Header
Task/ response
identifier
Bits 0 to 10 contain the number of the parameter specified in the request.
Owing to the length restriction of the bit field (11 bits), a parameter number (PNU) higher than
1999 must be converted to another code for use in the parameter identifier; the Page Select Bit in
the index is used for this purpose:
Parameter
area
Basic unit
Technology
board
In the case of a request, for example, which specifies parameter U280 (2280), therefore, PNU =
280 must be entered in the parameter identifier and bit 15 set in the index.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Parameter identifier
Index
PKE
IND
Parameter identifier
Index
PKE
IND
Parameter number (PNU)
SPM
Displayed
Input on OP1S
number
Pxxx, rxxx
2000 - 2999
Uxxx, nxxx
1000 - 1999
Hxxx, dxxx
3000 - 3999
Lxxx, cxxx
Parameter value
PWE
Parameter value
PWE
PNU in parameter
identifier
0 - 999
0 - 999
0 - 999
1000 - 1999
1000 - 1999
Start-Up
Trailer
Trailer
Page Select Bit
(index bit 15)
0
1
0
1
7-57