Parameter list
PNU
Description
Source for input signals, NAND element 4 (output = B9473)
U403
(2403)
As for U400
*
S00
(B207)
Source for input signals, NAND element 5 (output = B9474)
U404
(2404)
As for U400
*
S00
(B207)
Source for input signals, NAND element 6 (output = B9475)
U405
(2405)
As for U400
*
S00
(B207)
Source for input signals, NAND element 7 (output = B9476)
U406
(2406)
As for U400
*
S00
(B207)
Source for input signals, NAND element 8 (output = B9477)
U407
(2407)
As for U400
*
S00
(B207)
Source for input signals, NAND element 9 (output = B9478)
U408
(2408)
As for U400
*
S00
(B207)
Source for input signals, NAND element 10 (output = B9479)
U409
(2409)
As for U400
*
S00
(B207)
Source for input signals, NAND element 11 (output = B9480)
U410
(2410)
As for U400
*
S00
(B207)
Source for input signals, NAND element 12 (output = B9481)
U411
(2411)
As for U400
*
S00
(B207)
11.69 Storage elements, timers and binary signal selector switches
Only active with optional technology software S00
RS flipflops
RS flipflops with SET (Q=1) and RESET (Q=0) (priority: 1
U415
Source for SET and RESET for RS flipflop 1
(2415)
(Outputs: Q = B9550, /Q = B9551)
*
i001
Source for SET
S00
i002
Source for RESET
(B210)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U416
Source for SET and RESET for RS flipflop 2
(2416)
(outputs: Q = B9552, /Q = B9553)
*
As for U415
S00
(B210)
U417
Source for SET and RESET for RS flipflop 3
(2417)
(outputs: Q = B9554, /Q = B9555)
*
As for U415
S00
(B210)
11-136
FB 203
FB 204
FB 205
FB 206
FB 207
FB 208
FB 209
FB 210
FB 211
st
nd
RESET, 2
SET). RESET setting is enabled on POWER ON.
FB 215
FB 216
FB 217
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 3
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
6RX1700-0AD76