Start-Up
Input of motor data
4
In the parameters below, the motor data must be entered as specified on the motor rating plate.
P100 . . . Rated armature current (in amps)
P101 . . . Rated armature voltage (in volts)
P102 . . . Rated field current (in amps)
P104 . . . Speed n
P105 . . . Armature current I
P106 . . . Speed n
P107 . . . Armature current I
P108 . . . Maximum operating speed n
P109 . . . 1 = speed-dependent current limitation active
P114 . . . Thermal time constant of motor (in minutes)
(if necessary: activate fault signal F037 with P820!)
Actual speed sensing data
5
Operation with analog tacho
5.1
P083 = 1:
P741
Operation with pulse encoder
5.2
P083 = 2:
P140
Selecting a pulse encoder type (pulse encoder types see below)
0 No encoder/"Speed sensing with pulse encoder" function not selected
1 Pulse encoder type 1
2 Pulse encoder type 1a
3 Pulse encoder type 2
4 Pulse encoder type 3
1. Pulse encoder type 1
7-10
(in rpm)
1
(in amperes)
1
(in rpm)
2
(in amperes)
2
(in rpm)
3
The actual speed is supplied from the "Main actual value" channel (K0013)
(terminals XT.103, XT.104)
Tacho voltage at maximum speed (– 270,00V to +270,00V)
The actual speed is supplied by the pulse encoder (K0040)
Encoder with two pulse tracks mutually displaced by 90° (with/without zero marker)
Track 1
X173 28, 29
Track 2
X173 30, 31
Zero marker
X173 32, 33
see also Section 9.16
see also Section 9.16
see also Section 9.16
see also Section 9.16
see also Section 9.16
see also Section 9.16
see also Section 9.14
Heidenhain ROD
Teldix Rotaswitch Serie 26
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
6RX1700-0AD76