Parameter list
Overview of abbreviations
Example:
PNU
Description
Friction at 0% speed
P520
1)
*
Setting as % of converter rated DC current or converter rated torque
FDS 2)
8) 9)
(G153)
10)
1) An
under the parameter number means that the parameter requires confirmation, i.e. the altered value
*
does not take effect until the P key is pressed.
2) Abbreviation indicating that the parameter belongs to a data set (refers only to indexed parameters) (see
Section 9.11 "Switch over parameter sets")
FDS
Parameter belongs to the function data set (see Section 9.1, subsection "Data sets")
BDS
Parameter belongs to the BICO data set
3) Specification of parameter type
O2
Unsigned 16-bit value
I2
Signed 16-bit value
O4
Unsigned 32-bit value
I4
Signed 32-bit value
V2
Bit-coded quantity
L2
Nibble-coded quantity
4) Setting steps for access via PKW mechanism
5) Factory setting
6) Minimum setting required (P052) to allow display of the relevant parameter
Minimum access level required (P051) to allow modification of the relevant parameter
Online: The parameter can be changed in all converter operating states
Offline: The parameter can only be changed in converter operating states of ≥ o1.0
8)
S00
Parameter belongs to the technology software in the basic converter, S00 option
9) The "OP parameter number" (i.e. the number to be entered via the OP1S operator panel) is specified in
brackets in the "PNU" column for all parameters which are not "P parameters" or "r parameters": e.g. (2010)
under n010 or (2100) under U100.
10) The parameter is shown in the specified function diagram in Section 8 (here G153).
11-4
Value range
[Unit]
Steps
0.0 to 100.0
[%]
0.1% 4)
(see Section 9.1, subsection "Data sets")
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
P051 ≥ 20
FS=0.0 5)
Online 6)