05.05
PNU
Description
U118
Source for binector/connector converter for GSST3
(2118)
Binectors which must be converted to connector K9020
*
st
(G172)
i001:
1
binector (bit 0)
nd
(G174)
i002:
2
binector (bit 1)
...
th
i016:
16
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U119
Parameters for the Trace function of DriveMonitor
(2119)
*
This parameter is a setting for the exchange of process data between
DriveMonitor and the SIMOREG converter. It must not be changed!
11.60 Mathematical functions
Only active with optional technology software S00
Adder / subtractor
The 3 operands of a function block are selected by 3 indices each of a parameter.
U120 to U131:
The connectors selected via indices i001 and i002 are added, the connector selected via index i003 is subtracted.
U120 to U122 [SW 1.8 and later]:
The connectors selected via indices i004 and i005 are added, the connector selected via index i006 is subtracted.
The result is limited to -200.00 to +199.99% and applied to the connector stated.
Operands for 1st adder / subtractor (result = K9120)
U120
(2120)
Operands for 13th adder / subtractor (result = K9132)
*
(SW 1.8 and later)
S00
0 = Connector K0000
(B125)
1 = Connector K0001
etc.
Operands for 2nd adder / subtractor (result = K9121)
U121
(2121)
Operands for 14th adder / subtractor (result = K9133)
*
[SW 1.8 and later]
S00
0 = Connector K0000
(B125)
1 = Connector K0001
etc.
Operands for 3rd adder / subtractor (result = K9122)
U122
(2122)
Operands for 14th adder / subtractor (result = K9134)
*
[SW 1.8 and later]
S00
0 = Connector K0000
(B125)
1 = Connector K0001
etc.
th
U123
Operands for 4
(2123)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
th
U124
Operands for 5
(2124)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
th
U125
Operands for 6
(2125)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
adder / subtracter (result = K9123)
adder / subtracter (result = K9124)
adder / subtracter (result = K9125)
Value range
[Unit]
Steps
[SW1.4 and later]
All binector numbers
1
[SW1.4 and later]
All connector
FB 20
numbers
FB 32
1
All connector
FB 21
numbers
FB 33
1
All connector
FB 22
numbers
FB 34
1
All connector
FB 23
numbers
1
All connector
FB 24
numbers
1
All connector
FB 25
numbers
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 16
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 6
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 6
P052 = 3
P051 = 40
FS=0
off-line
Type: L2
Ind: 6
P052 = 3
P051 = 40
FS=0
off-line
Type: L2
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
11-107