Siemens 6RA7086-6KS22 Operating Instructions Manual page 533

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
P639
Source for the ramp-function generator setting values
*
Selection of the connectors that are connected as the ramp-function
generator setting values.
(G136)
i001
Setting value for the ramp-function generator output in state log.
"1" of the binector selected via P640
i002
Setting value for the ramp-function generator output if the drive
is not in state "Operating" (B0104=0) and the binector selected
via P640 is in state log. "0"
[i002 only available with SW 1.6 and later]
0 = Connector K0000
1 = Connector K0001
etc.
P640
Source for selection of "Set ramp-function generator"
*
Selection of binector to control the "Set ramp-function generator" function
BDS
0 = binector B0000
(G136)
1 = binector B0001
etc.
P641
Source for selection of "Bypass ramp-function generator"
*
Selection of binector to control the "Bypass ramp-function generator"
BDS
function
(G136)
0 = binector B0000
1 = binector B0001
etc.
P642
Source for variable positive limitation of main setpoint
*
Selection of connectors to be injected at the variable positive limitation of
the main setpoint.
(G135)
The lowest value in each case of the connectors selected via the 4 indices
is applied as the limit.
Note: Negative values at the selected connectors result in a negative
maximum value at the output of the limitation.
0 = connector K0000
1 = connector K0001
etc.
P643
Source for variable negative limitation of main setpoint
*
Selection of connectors to be injected at the variable negative limitation of
the main setpoint.
(G135)
The lowest value in each case of the connectors selected via the 4 indices
is applied as the limit.
Note: Positive values at the selected connectors result in a positive
minimum value at the output of the limitation.
0
= connector K0000
...
8
= connector K0008
= value as set in parameter P642 ∗ ( − 1)
9
10 = connector K0010
etc.
P644
Source for main setpoint
*
Selection of connector to be injected as the main setpoint
FDS
0 = connector K0000
(G135)
1 = connector K0001
etc.
P645
Source for additional setpoint
*
Selection of connector to be injected as an additional setpoint
FDS
0 = connector K0000
1 = connector K0001
(G135)
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 2
numbers
FS=167
1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All connector
Ind: 4
numbers
FS=2
1
Type: L2
All connector
Ind: 4
numbers
FS=9
1
Type: L2
All connector
Ind: 4
numbers
FS=206
1
Type: L2
All connector
Ind: 4
numbers
FS=0
1
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
≥ off-line
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
11-69