Siemens 6RA7086-6KS22 Operating Instructions Manual page 602

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
U431
Source for SET, D, STORE and RESET for D flipflop 2
(2431)
(outputs: Q = B9492, /Q = B9493)
*
As for U430
S00
(B211)
U432
Source for SET, D, STORE and RESET for D flipflop 3
(2432)
(outputs: Q = B9494, /Q = B9495)
*
As for U430
S00
(B211)
U433
Source for SET, D, STORE and RESET for D flipflop 4
(2433)
(outputs: Q = B9496, /Q = B9497)
*
As for U430
S00
(B211)
Timer 1 (0.000 to 60.000s) (output = B9580, inverted: B9581)
U440
Source for input signal and reset signal for timer element 1
(2440)
i001
Source for input signal
*
i002
Source for reset signal for the pulse generator (if U442=3)
S00
(in state "1", the pulse generator is set to "0")
(B215)
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
U441
Time for timer 1
(2441)
S00
(B215)
U442
Mode for timer 1
(2442)
0
ON delay
*
1
OFF delay
S00
2
ON / OFF delay
(B215)
3
Pulse generator with positive edge triggering
Timer 2 (0.000 to 60.000s) (output = B9582, inverted: B9583)
U443
Source for input signal and reset signal for timer element 2
(2443)
As for U440
*
S00
(B215)
U444
Time for timer 2
(2444)
S00
(B215)
U445
Mode for timer 2
(2445)
As for U442
*
S00
(B215)
Timer 3 (0.000 to 60.000s) (output = B9584, inverted: B9585)
U446
Source for input signal and reset signal for timer element 3
(2446)
As for U440
*
S00
(B215)
U447
Time for timer 3
(2447)
S00
(B215)
U448
Mode for timer 3
(2448)
As for U442
*
S00
(B215)
11-138
Value range
[Unit]
Steps
All binector numbers
FB 231
1
All binector numbers
FB 232
1
All binector numbers
FB 233
1
All binector numbers
FB 240
1
FB 240 0.000 to 60.000
[s]
0.001
0 to 3
FB 240
1
All binector numbers
FB 241
1
FB 241 0.000 to 60.000
[s]
0.001
0 to 3
FB 241
1
All binector numbers
FB 242
1
FB 242 0.000 to 60.000
[s]
0.001
0 to 3
FB 242
1
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: None
P052 = 3
FS=0.000
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.000
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.000
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents