Parameter list
PNU
Description
P193
Source for the actual armature voltage or EMF value for armature
*
current precontrol
The connector which is used as the actual armature voltage (if P162.F = 2)
(G162)
or EMF (if P162.F = 3) value for armature current precontrol is selected. The
selected connector value must correspond to half the motor armature
voltage or half the motor EMF in a 12-pulse series connection (P079 = 2).
0 = Connector K0000
1 = Connector K0001
etc.
11.11 Auto-reversing stage, armature gating unit
P192
Control word for the Alpha W limit (armature)
*
0
Continuous current:
FDS
Inverter stability limit for the delay angle of the armature
(G163)
converter (Alpha W) = value according to parameter P151
Intermittent current:
Alpha W = 165°
1
Inverter stability limit for the delay angle of the armature
converter (Alpha W) = value according to parameter P151
11.12 Speed controller
further parameters for the speed controller P550 - P567
Setting values for speed controller - actual value/setpoint processing
P200
Filter time for actual speed controller value
Filtering of the actual speed value by means of a PT1 element.
FDS
This filter setting is taken into account by the speed controller optimization
(G152)
run (P051=26).
P201
Band-stop 1: Resonant frequency
FDS
(G152)
P202
Band-stop 1: Quality
0
Quality = 0.5
FDS
1
Quality = 1
2
Quality = 2
(G152)
3
Quality = 3
P203
Band-stop 2: Resonant frequency
FDS
(G152)
P204
Band-stop 2: Quality
0
Quality = 0.5
FDS
1
Quality = 1
2
Quality = 2
(G152)
3
Quality = 3
P205
D element: Derivative-action time
FDS
(G152)
P206
D element: Filter time
FDS
(G152)
Indication of the active droop of the speed controller [SW 1.7 and later] 0.0 to 10.0
r217
(G151)
r218
Indication of the active integration time of the speed controller
(G151)
(G152)
r219
Display of effective P gain of speed controller
(G151)
(G152)
11-36
Value range
[Unit]
Steps
All connector
numbers
[SW 2.1 and later]
1
0 to 1
[as of SW 2.1]
1
0 to 10000
[ms]
1ms
1 to 140
[Hz]
1Hz
0 to 3
1
1 to 140
[Hz]
1Hz
0 to 3
1
0 to 1000
[ms]
1ms
0 to 100
[ms]
1ms
[%]
0.1%
0.010 to 10.000
[SW 1.7 and later]
[s]
0.001s
0.01 to 200.00
0.01
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
FS=287
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=1
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=1
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2